We are installing a track light system, we have power out to the track but cannot make the lights work?

The track section and floating live-end connector must be assembled so that polarity between conductors is maintained. NOTE: The floating live-end connector has a tab on one side and the track has an indentation which runs the length of the track channel.  Turn “Ground indicator” tab towards the ground groove on track to align ground tab with ground conductor. The ground is isolated by being offset from the neutral, and not on the opposite side.  Make sure to snap the connectors in the correct position relative to the power strips in the track.   If the connection blades are not oriented correctly inside the track, they will not get power. 