What is the acceptable standard for the FDL locations in regards to pole integrity? Example Pole is SSS 20 4C DM19AS FDLXX Side A: FDL3A Side C: FDL3C Is this acceptable?

To ensure the pole integrity, there should be at least 12” of separation between any openings in the pole shaft. In this case the hand hole is at 18” so the first festoon can be at 30 inches and the second at 42”.

SSS 20 4C DM19AS FDL2-6A/3-6C DDBXD