CONTINUITY TEST
Gnd to A  &  B to +12 

(should be almost the same value)

Resistance (Ohms)

Length (ft.)

3 Ω      to  6 Ω

100 ft

12 Ω    to  20 Ω

500 ft

34 Ω    to  40 Ω

1000 ft

68 Ω    to  80 Ω

2000 ft

102 Ω  to  120 Ω

3000 ft

130 Ω  to  160 Ω

4000 ft

 

EARTH GROUND TEST
All test values should be greater than 1,000 ohms.
COUTINUITY TEST
Readings between each terminal and earth ground shoud be infinite or "open."
 

 1st TERMINATOR TEST

Resistance (Ohms)

Length (ft.)

125 Ω

100 ft

150 Ω

500 ft

175 Ω

1000 ft

230 Ω

2000 ft

285 Ω

3000 ft

340 Ω

4000 ft

 

2nd TERMINATOR TEST

Resistance (Ohms)

Length (ft.)

62 Ω

100 ft

67 Ω

500 ft

72 Ω

1000 ft

78 Ω

2000 ft

85 Ω

3000 ft

90 Ω

4000 ft